Precision dehumidification, engineered.

Air, perfected. Humidity, controlled.

From ultra-slim ceiling units to industrial floor-standing systems — the full DBA dehumidifier range, showcased by DryEaz.

DBA-UTC20 ceiling-mounted dehumidifier

Powered by DBA

A complete humidity-control portfolio.

DryEaz is the regional showcase of DBA's full dehumidifier range — manufactured by DBA Electric Pte. Ltd., compliant with international certifications, and built for both commercial and industrial applications.

Visit dba.sg ↗

Technology

Three principles.
Every climate solved.

Choosing the right dehumidifier starts with understanding how it removes water from air. Each method excels in different conditions.

Refrigerant compressor dehumidifier Desiccant rotary dehumidifier Humidity control unit
01

Refrigerant (compressor)

The workhorse for everyday tropical climates. Air is drawn over a cold evaporator coil — moisture condenses, falls into a collection system, and dry air is returned to the room.

  • Best for ambient temperatures 5–40°C
  • Highest extraction per kWh in warm, humid air
  • Used across UTC, GEC, GE, GEX, and DH product lines
02

Desiccant (rotary)

A silica honeycomb wheel actively adsorbs water vapour — even at sub-zero temperatures where compressors stall. Continuous, precise, low-temperature drying.

  • Operates from −20°C to 40°C
  • Maintains RH 1–90% with high precision
  • Cold storage, pharma, lithium battery rooms, lyophilisation
03

Humidity Control Unit

Hybrid units that hold a target RH band by removing or adding moisture as needed. Wet-membrane evaporative humidification, isenthalpic and clean.

  • Two-way control around a setpoint (e.g. 50–55% RH)
  • UV-C sterilisation, RS485 BMS integration
  • Galleries, museums, wine cellars, data centres

Applications

Built for every environment.

Match the right unit to the room, the load, and the regulatory target.

Modern residential interior

Residential

Apartments, terraces, basements. Mobile or ceiling units handle 500–2,000 sq ft with quiet inverter compressors.

Suggested · DBA-DH65, DBA-X65, DBA-UTC68

Modern open-plan office

Commercial & Office

Retail, hotels, offices, gyms. Concealed ceiling-mount units distribute dry air through ductwork to multiple zones.

Suggested · DBA-UTC120, DBA-GEC145LD-HP

Industrial warehouse interior

Industrial

Warehouses, manufacturing, switchgear rooms. 280–550 L/day floor units with stainless tanks and 10 m drainage head.

Suggested · DBA-GE280LD-HP, GE400LD-HP, GE550LD-HP

Art gallery interior

Heritage & Art

Museums, galleries, archives, wine cellars. Humidity control units hold tight RH for collections and aging conditions.

Suggested · DBA-HC145, HC280, HC400

Pharmaceutical clean room

Cold & Pharma

Cold rooms, freezers, pharmaceutical packing. Rotary desiccant units deliver below-freezing dehumidification.

Suggested · DBA-DD210, DD550, DD850

Water damage restoration scene

Restoration & Recovery

Flood recovery, post-leak drying, construction site dry-out. Portable LGR units roll in and start drying immediately.

Suggested · DBA-GEX75, DBA-GEX110

Product range

Every model. Every capacity.

Six product families across the dehumidification spectrum. Most models are quoted on request — submit a brief and a colleague will follow up within one business day.

Ceiling-mount · ultra-slim

UTC Series

A 20cm slim profile that disappears into the ceiling. Whisper-quiet 39–50 dB operation. WiFi App, RS485 BMS, and UV-C sterilisation standard across the range.

↓ Download UTC catalog (PDF)

Configuration

  • Auto pump drainage · 1.8 m head
  • UV-C sterilisation lamp
  • Stainless steel mesh filter
  • Cold-rolled steel casing
  • Emergency stop button
  • 5 m humidity sensor cable
  • 8 m LCD control panel cable
  • Remote controller included

Control

  • Set humidity range 20–95%
  • Low / High fan speed
  • Fan and dehumidifying modes
  • Scheduled on/off timer
  • Power-off memory function
  • WiFi App control
  • BMS RS485 (Modbus)
  • Dry contact + water-leak port
DBA-UTC20

DBA-UTC20

Capacity20 L/day
Coverage200 – 400 sq ft
Airflow220 CMH
Noise39 dB(A)
Dimensions865 × 376 × 200 mm
Weight28 kg
View details →
DBA-UTC68

DBA-UTC68

Capacity68 L/day
Coverage800 – 1,000 sq ft
Airflow500 CMH
Noise48 dB(A)
Dimensions1,010 × 500 × 240 mm
Weight42 kg
View details →
DBA-UTC120

DBA-UTC120

Capacity120 L/day
Coverage1,300 – 1,500 sq ft
Airflow890 CMH
Noise50 dB(A)
Dimensions1,075 × 746 × 310 mm
Weight64 kg
View details →

Ceiling-mount · commercial

GEC Series

Higher static pressure and capacity for large floors and multi-room ducted systems. RS485 BMS standard; WiFi App on smaller models. Capacities from 68 to 550 L/day.

↓ Download GEC catalog (PDF)

Configuration

  • Drain pump (68 / 145 models)
  • UV-C sterilisation lamp
  • Stainless steel mesh filter
  • Cold-rolled steel casing
  • Emergency stop button
  • LCD control panel + remote
  • 5 m humidity sensor cable
  • 8 m control panel cable

Control

  • Set humidity range 20–95%
  • Fan and dehumidifying modes
  • Scheduled on/off timer
  • Fault detection & diagnosis
  • Power-off memory function
  • BMS RS485 (Modbus)
  • Water-leak sensor port
  • Fault indicator output 220V 6A
DBA-GEC68LD-HP

DBA-GEC68LD-HP

Capacity68 L/day
Coverage800 – 1,000 sq ft
Airflow500 CMH
Noise49 dB(A)
Dimensions970 × 525 × 345 mm
Weight44 kg
ConnectivityWiFi + RS485
View details →
DBA-GEC145LD-HP

DBA-GEC145LD-HP

Capacity145 L/day
Coverage1,500 – 1,700 sq ft
Airflow1,200 CMH
Noise50 dB(A)
Dimensions1,005 × 695 × 440 mm
Weight70 kg
ConnectivityRS485
View details →
DBA-GEC280LD

DBA-GEC280LD

Capacity280 L/day
Coverage2,500 – 3,000 sq ft
Airflow1,700 CMH
Noise58 dB(A)
Dimensions1,137 × 900 × 540 mm
Weight108 kg
Voltage380V 3N 50Hz
View details →
DBA-GEC400LD

DBA-GEC400LD

Capacity400 L/day
Coverage3,000 – 4,000 sq ft
Airflow3,250 CMH
Noise65 dB(A)
Dimensions1,270 × 1,200 × 605 mm
Weight210 kg
Voltage380V 3N 50Hz
View details →
DBA-GEC550LD

DBA-GEC550LD

Capacity550 L/day
Coverage4,000 – 5,000 sq ft
Airflow3,250 CMH
Noise65 dB(A)
Dimensions1,270 × 1,200 × 605 mm
Weight240 kg
Voltage380V 3N 50Hz
View details →

Portable · LGR restoration

GEX Series

Designed for rapid water-damage recovery. LLDPE rugged housing, fold-down handle with wheels, stackable for transport. WiFi App with full diagnostics on every model.

↓ Download GEX catalog (PDF)

Configuration

  • Pump drainage · 5 m head
  • Dust filter · washable / replaceable
  • LLDPE rugged housing
  • Rubber wheels + metal handle
  • 5 m drain hose included
  • 5 m Type G power cable
  • External ducting flange
  • Stackable for transport

Control

  • Set humidity range 30–90%
  • Manual purge button
  • Display: working hours
  • Display: air in/out + coil temp
  • Display: compressor current
  • Display: total power consumption
  • °C / °F selection
  • WiFi App + power-off memory
DBA-GEX75

DBA-GEX75

Capacity75 L/day
Coverage1,000 sq ft
Airflow420 CMH
Noise55 dB(A)
Dimensions560 × 345 × 450 mm
Weight29.2 kg
RefrigerantR290 / 0.2 kg
View details →
DBA-GEX110

DBA-GEX110

Capacity110 L/day
Coverage1,500 sq ft
Airflow1,000 CMH
Noise60 dB(A)
Dimensions705 × 445 × 530 mm
Weight45 kg
RefrigerantR290 / 0.235 kg
View details →

Industrial · floor-standing

GE Series

Heavy-duty floor-standing dehumidifiers for warehouses, factories, and large facilities. 10 m drain head, three-phase power, BMS-integrated. 280 to 550 L/day.

↓ Download Commercial catalog (PDF)

Configuration

  • Drain pump · 10 m head
  • Dust filter
  • Cold-rolled steel casing
  • Emergency stop button
  • LCD control panel
  • 3 m drain hose
  • 5 m power cable
  • Operating range 1–40°C

Control

  • Set humidity range 20–95%
  • Manual purge button
  • Low / High fan speed
  • Fan and dehumidifying modes
  • Scheduled on/off timer
  • Fault detection
  • Power-off memory function
  • BMS RS485 + dry contact
DBA-GE280LD-HP

DBA-GE280LD-HP

Capacity280 L/day
Coverage3,000 sq ft
Drain head10 m
Voltage380V 3N 50Hz
Dimensions820 × 465 × 1,775 mm
Weight160 kg
RefrigerantR410A / 1.7 kg
View details →
DBA-GE400LD-HP

DBA-GE400LD-HP

Capacity400 L/day
Coverage4,000 sq ft
Drain head10 m
Voltage380V 3N 50Hz
Dimensions1,200 × 540 × 1,740 mm
Weight230 kg
RefrigerantR410A / 1.45 kg × 2
View details →
DBA-GE550LD-HP

DBA-GE550LD-HP

Capacity550 L/day
Coverage5,000 sq ft
Drain head10 m
Voltage380V 3N 50Hz
Dimensions1,200 × 540 × 1,740 mm
Weight240 kg
RefrigerantR410A / 1.65 kg × 2
View details →

Humidity control · dehumidify + humidify

HC Series

Two-way humidity control units. Wet-membrane evaporative humidification combined with refrigerant dehumidification — hold a precise RH band for galleries, archives, wine cellars, data centres, and labs.

↓ Download Commercial catalog (PDF)

Configuration

  • Drain pump
  • UV-C sterilisation lamp
  • Dust filter
  • Emergency stop button
  • LCD control panel
  • 5 m power cable
  • Self-cleaning water tank
  • Filtered water input

Control

  • Set humidity range 20–95%
  • Manual purge button
  • Auto / Humidify / Dehumidify modes
  • Scheduled on/off timer
  • Fault detection
  • Power-off memory function
  • BMS RS485 + dry contact
  • Water-leak sensor port
DBA-HC68

DBA-HC68

Dehumidify68 L/day
Humidify3 kg/hr
Coverage1,000 sq ft
Voltage220–240V 50Hz
Dimensions800 × 500 × 1,650 mm
Weight150 kg
View details →
DBA-HC145

DBA-HC145

Dehumidify145 L/day
Humidify5 kg/hr
Coverage1,500 sq ft
Voltage220–240V 50Hz
Dimensions800 × 500 × 1,850 mm
Weight150 kg
View details →
DBA-HC280

DBA-HC280

Dehumidify280 L/day
Humidify10 kg/hr
Coverage3,000 sq ft
Voltage380V 3N 50Hz
Dimensions1,200 × 600 × 2,200 mm
Weight290 kg
View details →
DBA-HC400

DBA-HC400

Dehumidify400 L/day
Humidify15 kg/hr
Coverage4,000 sq ft
Voltage380V 3N 50Hz
Dimensions1,400 × 750 × 2,200 mm
Weight360 kg
View details →
DBA-HC550

DBA-HC550

Dehumidify550 L/day
Humidify20 kg/hr
Coverage5,000 sq ft
Voltage380V 3N 50Hz
Dimensions1,400 × 750 × 2,200 mm
Weight380 kg
View details →

Desiccant · low temperature

DD Series

'ProFlute' desiccant rotor with PTC ceramic reactivation heater. Operates from −20°C to 40°C, holds 1–90% RH — the choice for cold rooms, lithium battery production, and pharmaceuticals.

↓ Download Commercial catalog (PDF)

Configuration

  • 'ProFlute' desiccant rotor
  • PTC ceramic heater
  • 7-inch LCD display panel
  • Dust filter
  • 5 m power cable
  • Operating range −20 to 40°C
  • Process & reactivation airflows
  • Robust steel construction

Control

  • Set humidity range 1–90%
  • Fault detection
  • Humidity data log
  • Power-off memory function
  • BMS RS485 (Modbus)
  • Multi-stage safety protection
  • Phase & surge protection
  • Centralised remote control
DBA-DD210

DBA-DD210

Capacity1 kg/hr
Process airflow350 CMH
Reactivation airflow35 CMH
Voltage220–240V 50Hz
Dimensions491 × 430 × 346 mm
Weight20 kg
View details →
DBA-DD550

DBA-DD550

Capacity2.5 kg/hr
Process airflow550 CMH
Reactivation airflow180 CMH
Voltage220–240V 50Hz
Dimensions802 × 615 × 567 mm
Weight52 kg
View details →
DBA-DD850

DBA-DD850

Capacity7.5 kg/hr
Process airflow850 CMH
Reactivation airflow340 CMH
Voltage380V 3N 50Hz
Dimensions750 × 750 × 1,700 mm
Weight120 kg
View details →

Resources

Product catalogs.

Detailed specifications, configuration tables, dimensional drawings, and control matrices.

How to size

Match capacity to space.

A starting reference. The right model depends on insulation, occupancy, and target RH — share your room with us and we will model it.

Floor areaRecommended typeSuggested model
200 – 400 sq ftUltra-slim ceilingDBA-UTC20
500 – 1,000 sq ftMobile / ceiling slimDBA-DH65 · DBA-X65 · DBA-UTC68
1,000 – 1,500 sq ftMobile / ceiling slimDBA-GEX75 · DBA-UTC120
1,500 – 2,000 sq ftCommercial ceiling / mobileDBA-C150 · DBA-GEC145LD-HP
2,500 – 3,000 sq ftCommercial ceilingDBA-GEC280LD
3,000 – 4,000 sq ftIndustrial / commercial ceilingDBA-GE280LD-HP · DBA-GEC400LD
4,000+ sq ftIndustrial floor-standingDBA-GE400LD-HP · DBA-GE550LD-HP

Questions

Everything you might want to know.

What is the difference between a refrigerant and a desiccant dehumidifier?

A refrigerant unit cools incoming air past its dew point — water condenses and is drained. It is most efficient in warm, humid air (5–40°C) and is the right choice for tropical Singapore homes and offices. A desiccant unit uses a silica wheel that adsorbs water vapour directly, so it works at low temperatures (down to −20°C) where refrigerant coils would frost over. Choose desiccant for cold rooms, pharma, lithium-battery production, or precision laboratories.

How big a unit do I need for my space?

As a rule of thumb, a well-insulated home needs 0.5–1 L/day per 10 sq ft to hold a comfortable 50–60% RH. Heavy moisture loads (basements, indoor pools, post-flood drying) can demand 5–10× more. The sizing table above is a starting reference — share your floor plan and we will size it precisely.

What humidity should I aim for?

For human comfort and to discourage mould and dust mites, 50–60% RH is the sweet spot. Below 40% the air starts to feel dry; above 65% you risk condensation, mould growth, and dust-mite proliferation. Galleries and wine cellars typically target 50–55% with tighter ±2% control via the HC humidity-control series.

Do ceiling-mount units need ductwork?

Yes — ceiling units use short-run ductwork to distribute dry air through a void above the ceiling, with grilles in each zone. This lets one unit serve multiple rooms quietly. Ultra-slim UTC models install in just 200–310 mm of plenum height.

How loud are these units?

UTC ceiling units run 39–50 dB at 3 m — quieter than a quiet conversation, and noticeably quieter than a typical portable air conditioner. Commercial GEC ceiling units sit at 49–65 dB. Industrial floor-standing GE units are louder by design and best installed in plant rooms.

Can I integrate units with my building management system?

Yes. Every UTC, GEC, GE, HC and DD model includes RS485 with Modbus, allowing direct integration with BMS platforms for centralised setpoint control, alarms, and runtime telemetry. Smaller UTC and GEC68 models also offer WiFi App control.

Can a dehumidifier replace my air conditioner?

No — but it complements one. An air conditioner cools and removes some moisture as a byproduct. A dehumidifier removes moisture far more efficiently per kWh and lets you run your AC at higher temperatures while still feeling cool, because dry air feels cooler. In tropical climates, running both together typically saves energy versus running an AC alone.

What does "LGR" mean in the GEX series?

LGR stands for Low-Grain Refrigerant — a design that pre-cools incoming air before the evaporator, allowing extraction at lower humidity levels than standard refrigerant units. LGR is the standard for restoration and water-damage recovery, where you need to drive a room down to 30–35% RH in a hurry.

Where is DryEaz based and what is the link to DBA?

DryEaz is a regional showcase site for the DBA dehumidifier line. DBA Electric Pte. Ltd. is the manufacturer; full product information lives at dba.sg. Use this site to evaluate the range and request a quote — a colleague will follow up with availability and pricing.

How fast can I get a unit?

Featured models (DBA-DH65, DBA-X65, DBA-C150) ship from stock with fast delivery in Singapore and the region. Larger ceiling and industrial units typically ship within 1–2 weeks. Custom or container loads — up to 8 weeks.

Get a quote

Let's size it.
Together.

Tell us about the space, the load, and the target. A specialist colleague will reply within one business day with a recommended configuration and price.

We will reply within one business day. No spam, ever.